The amount of ventilation can be reduced to 1 300 in effect 50 less but 2 conditions must be met effective 1 1 18.
Attic venting requirements irc.
2018 international residential code.
Code requirements the international building code.
Chapter 8 roof ceiling construction.
Vented attics shall have a minimum net free ventilation area at least 1 300 of the area of the vented space.
Here s an example using the shortcut for the 1 150 code minimum.
The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures.
Typically building codes include minimum requirements applicable to attic ventilation.
Proper attic ventilation consists of a balance between air intake at your eaves soffits or fascias and air exhaust at or near your roof ridge.
Contains sections covering roof framing roof sheathing and roof ventilation.
Attic square footage 4 square inches of exhaust and square inches of intake net free area needed.
As an example of what you can find in chapter 8 of the 2018 irc see.
R806 1 ventilation required enclosed attics and enclosed rafter spaces formed where ceilings are applied directly to the underside of roof rafters shall have cross ventilation for each separate space by ventilating openings protected against the entrance of rain or snow.
Allows cool dry air to enter the attic.
Between half and two thirds of the provided ventilation shall be installed at the eaves.
To calculate the allowable irc exception to the miniumum that is 1 300 ratio here s the shortcut.
The following product options will allow you to achieve an intake nfva of 528 square inches.
Attic floor is defined as length x width floor of the attic.
Choose one of the following products to meet the recommended intake nfva of 528 square inches.
The following are the requirements taken directly from the irc.
The ventilation openings shall have a least dimension of 1 16 inch 1 6 mm minimum and 1 4 inch 6 4 mm maximum.
Proper attic ventilation can be an impor tant performance consideration when design ing and installing steep slope roof systems.
The minimum amount of attic ventilation remains 1 150 1 square foot of net free area for every 150 square feet of attic floor space.
The roofing industry also has practical guide lines for attic ventilation.
Federal housing authority recommends a minimum of at least 1 square foot of attic ventilation evenly split between intake and exhaust for every 300 square feet of attic floor space.
The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process.
Ventsure inflow intake vent.