The higher the r value the better the thermal performance of the insulation.
Attic r factor in nc.
The building code requires certain r values for the state based on different locations and climates.
Roofs or ceilings need to be insulated to a minimum of r 38 in zone 3 or r 49 in zone 4.
The prescriptive r values for a new house in the new 2018 nc building code are as follows.
Insulation level are specified by r value.
These r values are a sum meaning this should be the total r value once you add up the entire depth of insulation.
Recommended insulation levels for retrofitting existing wood framed buildings.
Having the correct amount of attic insulation can help you maintain a comfortable temperature throughout your home and help save money on your energy bills plus prevent major issues like ice dams in the winter.
Insulation levels are specified by r value.
Notes from previous r value chart a.
10 13 means r 10 continuous insulated sheathing on the interior or exterior of the home or r 13 cavity insulation at the interior of the.
R 19 on floor system garage ceiling.
If you think you re among the 90 of us homes that are under insulated 1 performing a simple insulation inspection will help you determine your insulation needs.
Based on your zone use the table to find out how much insulation you need to add if you.
For example if you have a type of insulation that has an r value of r 5 per inch of thickness you will need a depth of 6 inches of this insulation installed in your attic to reach r 30 if you live in zones 2 or 3.
Add the right kind of insulation.
The map below shows the most cost effective levels of insulation for the different climate zones in the u s.
U factors and shgc are maximums.
The shgc column applies to all glazed fenestration.
Insulation which is compressed will not give you its full rated r value.
This can happen if you add denser insulation on top of lighter insulation in an attic.
Adding insulation in your home s attic can help control utility bills.
It also happens if you place batts rated for one thickness into a thinner cavity such as placing r 19 insulation rated for 6 1 4 inches into a 5 1 2 inch wall cavity.
R value is a measure of insulation s ability to resist heat traveling through it.
Heating and cooling costs continue to rise.
Depending on where you live and the part of your home you re insulating walls crawlspace attic etc you ll need a different r value.
Walls need to be insulated to a minimum of r 20 if the insulation is between the studs or r 15 r 5 if the insulation is a combination of insulation between the studs and a continuous layer of exterior insulation in zones 3 or 4.
The recommended level for most attics is to insulate to r 38 or about 10 to 14 inches depending on insulation type.
Recommended home insulation r values.
Wake county is 4a zone so walls floors ceilings and slab insulation values are unchanged from the 2012 code.
The higher the r value the better the thermal performance of the insulation.